Autonomous AI agents found an unknown flaw in an open-source medical imaging tool and exploited it in 11 minutes, going from mapping the application's API to writing files outside its storage directory, according to HIPAA Journal. The attacker's main instruction to the agents was to "obtain shell access."

The targets were universities in East Asia, not U.S. hospitals, and no patient data breach has been reported. The software involved, MONAI Label, is a research tool for labeling medical images. Academic medical centers and hospitals with research teams run annotation and AI tools like it, sometimes on the same network as clinical systems. The same default settings the attackers used could be running in your environment.

The agents needed one instruction and 11 minutes

The campaign ran from September 8 to September 10, 2026, and researchers at Amazon Threat Intelligence attribute it to a China-linked threat actor, BleepingComputer reported. The attacker used a publicly hosted instance of Cairn, an open-source defensive pen testing framework, and left most of the work to its agents.

The agents mapped MONAI Label's API, found a path traversal flaw, and used it to write files to any location on the server. In a later session, they planted a Python reverse shell that loads every time Python starts, then triggered an API endpoint to get root access.

Once the agents had a working exploit, the attacker gave them a proxy into a second university network running the same software. Researchers believe the same zero-day opened that network too, and the agents were then pointed at other devices on it.

Go deeper: Researchers document ransomware run entirely by an AI agent

Failed attempts still leave a trail in the logs

Against a Redis server, the agents ran for 16 hours and took 148 actions in sequence without a person stepping in, HIPAA Journal reported. On a university GPU server, they tried more than 30,000 credential combinations over six hours, according to BleepingComputer. Both attempts failed.

Activity at that volume shows up in server logs. It only helps if someone, or something, is watching those logs and acting on what they show.

MONAI Label ships with authentication turned off

MONAI Label versions 0.8.5 and earlier are affected, and version 0.8.6 fixes the flaw, according to the project's security advisory published November 18. The advisory notes that authentication is turned off by default, so in a default setup any device that can reach the server can exploit it.

That default makes sense for a researcher running the tool on a lab workstation. It becomes a problem once the server is reachable from a wider network or the internet, which is where the agents found it.

Patched DCMTK may not have reached your vendor's build

The same week brought separate flaws in software that does a similar job. On November 20, HIPAA Journal reported two more flaws in the OFFIS DCMTK toolkit, which imaging products use to store and move DICOM files. These are unrelated to the AI campaign. The more serious one, rated 9.1 out of 10, lets an unauthenticated network peer trigger the archive's own cleanup and delete stored studies.

Read also: DICOM Toolkit flaws raise security concerns for medical imaging software

The DCMTK developer fixed both flaws in version 3.7.1 on October 15, 2026. Products that bundle the DCMTK archive server, including some Debian, Ubuntu, and Fedora package sources, may still carry the vulnerable code.

Abhinav Agarwal, the independent researcher who found the flaws, put the inventory problem plainly: "An SBOM line that says 'DCMTK' doesn't answer the question. Hospitals and suppliers need to know whether the archive server or its backend is in the build, which revision it came from, and whether both fixes made it downstream."

For an IT director, that means asking imaging vendors which component versions ship inside their products, then confirming the answer instead of assuming the upstream patch reached you.

Your team can't out-triage an agent by hand

The Amazon researchers who tracked the campaign warned that AI agents can find and exploit vulnerabilities faster than security teams can react to an alert. Their advice was to rely more on automated detection and response, with people reviewing outcomes rather than every individual action.

Paubox research found that 89% of healthcare IT leaders believe AI and machine learning are critical for threat detection, but only 44% use them, according to the Healthcare IT is dangerously overconfident about email security report. This campaign shows the cost of that gap: an agent that needs 11 minutes to go from first contact to a working exploit won't wait for someone to open a ticket.

The same rule applies to every system that faces outside traffic, including HIPAA compliant email, where Paubox inbound email security uses generative AI to flag threats before a message reaches staff.

Steps for imaging systems this week

  • Find every MONAI Label instance and update it to version 0.8.6 or later
  • Turn on authentication for MONAI Label wherever it runs, since it is off by default
  • Confirm that no imaging server, DICOM archive, or annotation tool is reachable from the internet
  • Ask imaging vendors whether their products bundle the DCMTK archive server and which revision they ship
  • Place imaging and research servers on their own network segment, so one compromised tool can't reach the rest of the network
  • Review alerting on imaging servers, so unusual file writes or new outbound connections trigger a response without waiting on a manual review

FAQs

What is a zero-day vulnerability?

A zero-day is a flaw the software's maintainers don't know about yet, so no fix exists when attackers first use it. In this case, the MONAI Label maintainers published a fix after researchers reported the flaw.

What is MONAI Label?

MONAI Label is an open-source medical imaging application that uses AI to help researchers label medical images.

Was patient data exposed in this attack?

No patient data breach has been reported. The targets were educational institutions in East Asia, and reporting so far describes server takeover rather than theft of patient records.

Does HIPAA cover medical imaging servers?

Yes, when they create, receive, store, or transmit protected health information for a covered entity or business associate. The HIPAA Security Rule requires a risk analysis that includes those systems. Go deeper: HIPAA compliant email: the definitive guide